Evaluating solid phase (micro-) extraction tools to analyze freely ionizable and permanently charged cationic surfactants

期刊

ANALYTICA CHIMICA ACTA
卷 1002, 期 -, 页码 26-38

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2017.11.051

关键词

WCX-SPE; Cationic surfactants; Quaternary ammonium compounds; Glass binding; PA-SPME; LC-MS/MS; pH-dependent sorption; Passive sampling; Sample preparation

资金

  1. Unilever, Safety & Environmental Assurance Centre (SEAC), Colworth Science Park, U.K. [CH-2012-0283]

向作者/读者索取更多资源

Working with and analysis of cationic surfactants can be problematic since aqueous concentrations are difficult to control, both when taking environmental aqueous samples as well as performing laboratory work with spiked concentrations. For a selection of 32 amine based cationic surfactants (including C8- to C18-alkylamines, C14-dialkyldimethylammonium, C8-tetraalkylammonium, benzalkonium and pyridinium compounds), the extraction from aqueous samples was studied in detail. Aqueous concentrations were determined using solid phase extraction (SPE; 3 mL/60 mg Oasis WCX-SPE cartridges) with recoveries of >= 80% for 30 compounds, and >= 90% for 16 compounds. Sorption to glassware was evaluated in 120 mL flasks, 40 mL vials and 1.5 mL autosampler vials, using 15 mM NaCl, where the glass binding of simple primary amines and quaternary ammonium compounds increased with alkyl chain length. Sorption to the outside of pipette tips (<= 20% of total amount in solution) when sampling aqueous solutions may interfere with accurate measurements. Polyacrylate solid phase microextraction (PA-SPME) fibers with two coating thicknesses (7 and 35 mm) were tested as potential extraction devices. The uptake kinetics, pH-dependence and influence of ionic strength on sorption to PA fibers were studied. Changing medium from 100 mM Na+ to 10 mM Ca2+ decreases K-fw with one order of magnitude. Results indicate that for PA-SPME neutral amines are absorbed rather than adsorbed, although the exact sorption mechanism remains to be elucidated. Further research remains necessary to establish a definitive applicability domain for PA-SPME. However, results indicate that alkyl chain lengths >= 14 carbon atoms and multiple alkyl chains become problematic. A calibration curve should always be measured together with the samples. In conclusion, it seems that for amine based surfactants PA-SPME does not provide the reliability and reproducibility necessary for precise sorption experiments, specifically for alkyl chain lengths beyond 12 carbon atoms. (c) 2017 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据