Identification of Chronic Active Multiple Sclerosis Lesions on 3T MRI

期刊

AMERICAN JOURNAL OF NEURORADIOLOGY
卷 39, 期 7, 页码 1233-1238

出版社

AMER SOC NEURORADIOLOGY
DOI: 10.3174/ajnr.A5660

关键词

-

资金

  1. National Institute of Neurological Disorders and Stroke

向作者/读者索取更多资源

MR imaging-pathologic studies have reported that paramagnetic rims on 7T susceptibility-based MR imaging identify, in vivo, a subset of MS lesions with compartmentalized inflammation at the lesion edge and associated remyelination failure. High-resolution T2* and phase MR imaging were collected in 20 patients with MS at 3T and 7T. Phase rims were seen in 34 lesions at 7T and in 36 lesions at 3T by consensus. Inter- and intra-rater reliability were substantial/good both at 3T and 7T analysis. Nearly all 7T paramagnetic rims can also be seen at 3T. Imaging at 3T opens the possibility of implementing paramagnetic rims as an outcome measure. BACKGROUND AND PURPOSE: MR imaging-pathologic studies have reported that paramagnetic rims on 7T susceptibility-based MR imaging identify, in vivo, the subset of MS lesions with compartmentalized inflammation at the lesion edge and associated remyelination failure. Here, we assessed the reliability of detecting these rims on high-resolution 3T phase images. MATERIALS AND METHODS: High-resolution T2* and phase MR imaging was collected in 20 patients with MS at 3T (3D segmented EPI, 0.65 mm(3)) and 7T (2D gradient-echo, 0.2 x 0.2 x 1 mm) MR imaging. In each case, 5 discrete chronic (nonenhancing) MS lesions were selected on T2 FLAIR images for rim evaluation. Five raters experienced in MS imaging contributed to the rim assessment, of whom 3 worked independently on 3T data, and 2, on 7T data. Consensus agreement was reached for both 3T and 7T rim evaluations. Discrepancies between 3T and 7T were discussed, and consensus was reached. RESULTS: Phase rims were seen in 34 lesions at 7T and in 36 lesions at 3T by consensus. Inter- and intrarater reliability were substantial/good both at 3T and 7T analysis (Cohen , >0.71). Based on consensus agreement, the reliability of rim visualization at 3T versus 7T was 0.78 () with a pair-wise agreement of 90%. More lesions were judged to be false-positive or false-negative at 3T than at 7T. CONCLUSIONS: Nearly all 7T paramagnetic rims can also be seen at 3T. Imaging at 3T opens the possibility of implementing paramagnetic rims as an outcome measure in multicenter, MR imaging-based clinical trials aimed at treating perilesional persistent inflammation and its potential effects on remyelination.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据