4.8 Article

Chemiresistive Graphene Sensors for Ammonia Detection

期刊

ACS APPLIED MATERIALS & INTERFACES
卷 10, 期 18, 页码 16169-16176

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acsami.8b00853

关键词

graphene; chemiresistive sensors; porphyrin; Co(tpfpp)ClO4; NH3 sensors

资金

  1. ARO-ISN UARC, Graphene-Based FET Biosensor Platform for Screening Food and Water [W911NF-13-D-0001 T.O.9]
  2. Triton Systems, Low Cost Repeatable Bio-FET Sensing [TSI-2445-14-103591]
  3. AFOSR FATE MURI, FATE: Foldable and Adaptive Two-Dimensional Electronics [FA9550-15-1-0514]
  4. Center for Integrated Quantum Materials under NSF [DMR-1231319]
  5. National Science Foundation [DMR-1410718]
  6. Division Of Materials Research
  7. Direct For Mathematical & Physical Scien [1410718] Funding Source: National Science Foundation

向作者/读者索取更多资源

The primary objective of this work is to demonstrate a novel sensor system as a convenient vehicle for scaled-up repeatability and the kinetic analysis of a pixelated testbed. This work presents a sensor system capable of measuring hundreds of functionalized graphene sensors in a rapid and convenient fashion. The sensor system makes use of a novel array architecture requiring only one sensor per pixel and no selector transistor. The sensor system is employed specifically for the evaluation of Co(tpfpp)ClO4 functionalization of graphene sensors for the detection of ammonia as an extension of previous work. Co(tpfpp)ClO4 treated graphene sensors were found to provide 4-fold increased ammonia sensitivity over pristine graphene sensors. Sensors were also found to exhibit excellent selectivity over interfering compounds such as water and common organic solvents. The ability to monitor a large sensor array with 160 pixels provides insights into performance variations and reproducibility critical factors in the development of practical sensor systems. All sensors exhibit the same linearly related responses with variations in response exhibiting Gaussian distributions, a key finding for variation modeling and quality engineering purposes. The mean correlation coefficient between sensor responses was found to be 0.999 indicating highly consistent sensor responses and excellent reproducibility of Co(tpfpp)ClO4 functionalization. A detailed kinetic model is developed to describe sensor response profiles. The model consists of two adsorption mechanisms-one reversible and one irreversible and is shown capable of fitting experimental data with a mean percent error of 0.01%.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据