4.3 Article

Behavior and Design of Slender Rectangular Concrete Columns Longitudinally Reinforced with Fiber-Reinforced Polymer Bars

期刊

ACI STRUCTURAL JOURNAL
卷 115, 期 2, 页码 311-322

出版社

AMER CONCRETE INST
DOI: 10.14359/51701131

关键词

design approach; effective flexural stiffness; fiber-reinforced polymer (FRP) bars; finite element (FE) analysis; rectangular column; reinforced concrete

资金

  1. National Key R&D Program of China [2017YFC0703003]
  2. Natural Science Foundation of China [51678433]
  3. Fundamental Research Funds for the Central Universities [0200219151]
  4. Project of Shanghai Science Technology Commission [15DZ1203502]

向作者/读者索取更多资源

Fifteen slender rectangular reinforced concrete (RC) columns with longitudinal glass fiber-reinforced polymer (FRP) bars were tested under compression in this paper. Results showed that all columns with varying length-to-depth ratios and eccentricity ratios failed by concrete crushing, and no rupture of FRP bars was experienced. Moreover, validated nonlinear finite element model was used to perform a detailed parametric study of 27,000 FRP-RC columns using Opensees. Based on parametric analysis results in conjunction with the moment magnifier method, a refined design equation of the effective flexural stiffness EI was then statistically derived to determine the second-order bending moments. On this basis, a design approach was proposed for slender FRP-RC rectangular columns, in which the contribution of FRP bars in compression to the strength of sections was taken into account. The proposed approach is more consistent and accurate than existing design methods by comparing their predictions with available experimental results of 46 columns.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据