4.7 Article

HIGH-RESOLUTION LINEAR POLARIMETRIC IMAGING FOR THE EVENT HORIZON TELESCOPE

期刊

ASTROPHYSICAL JOURNAL
卷 829, 期 1, 页码 -

出版社

IOP PUBLISHING LTD
DOI: 10.3847/0004-637X/829/1/11

关键词

black hole physics; Galaxy: center; techniques: high angular resolution; techniques: image processing; techniques: interferometric

资金

  1. National Science Foundation [AST-1310896, AST-1312034, AST-1211539, AST-1440254]
  2. Gordon and Betty Moore Foundation [GBMF-3561]
  3. NSF [AST1312651, CGV-1111415]
  4. NASA [TCAN NNX14AB47G]
  5. NSF Graduate Fellowship
  6. NASA through the Fermi Guest Investigator Program
  7. Direct For Mathematical & Physical Scien
  8. Division Of Astronomical Sciences [1310896, 1312651] Funding Source: National Science Foundation
  9. Division Of Astronomical Sciences
  10. Direct For Mathematical & Physical Scien [1126433] Funding Source: National Science Foundation

向作者/读者索取更多资源

Images of the linear polarizations of synchrotron radiation around active galactic nuclei (AGNs) highlight their projected magnetic field lines and provide key data for understanding the physics of accretion and outflow from supermassive black holes. The highest-resolution polarimetric images of AGNs are produced with Very Long Baseline Interferometry (VLBI). Because VLBI incompletely samples the Fourier transform of the source image, any image reconstruction that fills in unmeasured spatial frequencies will not be unique and reconstruction algorithms are required. In this paper, we explore some extensions of the Maximum Entropy Method (MEM) to linear polarimetric VLBI imaging. In contrast to previous work, our polarimetric MEM algorithm combines a Stokes I imager that only uses bispectrum measurements that are immune to atmospheric phase corruption, with a joint Stokes Q and U imager that operates on robust polarimetric ratios. We demonstrate the effectiveness of our technique on 7 and 3 mm wavelength quasar observations from the VLBA and simulated 1.3 mm Event Horizon Telescope observations of Sgr A* and M87. Consistent with past studies, we find that polarimetric MEM can produce superior resolution compared to the standard CLEAN algorithm, when imaging smooth and compact source distributions. As an imaging framework, MEM is highly adaptable, allowing a range of constraints on polarization structure. Polarimetric MEM is thus an attractive choice for image reconstruction with the EHT.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据