期刊
FRICTION
卷 6, 期 4, 页码 387-394出版社
SPRINGEROPEN
DOI: 10.1007/s40544-017-0166-6
关键词
chromia coating; fracture toughness; plasma spray; critical plasma spray parameter; critical depth
资金
- MHRD, Govt. of India
In this experimental study, chromium oxide powder was sprayed on a low-carbon steel substrate using the atmospheric plasma spray process. The current and standoff distances (SODs) were varied to study their effect on the fracture toughness of the coatings. Theoretically, as the arc current increases, the melting of the ceramic oxide should increase and this in turn should lead to the formation of a dense coating. However, it was observed that if the arc power is too high and because the particle size of the powder is small (approximately 30 m), the particles tend to fly away from the plasma core. Similarly, an appropriate SOD should provide the particles with more melting time, thus resulting in a dense coating. On the other hand, a larger SOD leads to the solidification of the molten particles before the droplets can reach the substrate. All these effects may lead to substantial variation in the fracture toughness of the coating. The present paper attempts to correlate the plasma spraying parameters and microstructure of the coating with the fracture toughness and other primary coating properties.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据