3.8 Proceedings Paper

A Comparative Study of Sinusoidal PWM and Third Harmonic Injected PWM Reference Signal on Five Level Diode Clamp Inverter

期刊

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.egypro.2016.05.020

关键词

DC-MLI; SPWM; Harmonic Injected PWM; PD; POD; APOD; THDV

向作者/读者索取更多资源

This paper present the comparative modulation of Sinusoidal PWM and Third Harmonic Injected PWM Reference signal with carrier signal PD, POD, and APOD on 5 Level Diode Clamp on a R-L load. All of process are simulate with computer program MATLAB/Simulink. The result of simulation has shown value of THDV line-line output voltage on both SPWM inverter and Third Harmonic Injection modulation inverter with PD carrier signal generate a minimum THDV. (C) 2016 Published by Elsevier Ltd.