4.7 Article

Quantitative assessment of hepatic function: modified look-locker inversion recovery (MOLLI) sequence for T1 mapping on Gd-EOB-DTPA-enhanced liver MR imaging

期刊

EUROPEAN RADIOLOGY
卷 26, 期 6, 页码 1775-1782

出版社

SPRINGER
DOI: 10.1007/s00330-015-3994-7

关键词

T1 map; Gadoxetic acid; Magnetic resonance imaging; MOLLI; Liver function estimation

资金

  1. National Research Foundation of Korea (NRF) - Ministry of Education [2013R1A1A2A10066037]
  2. National Research Foundation of Korea [2013R1A1A2A10066037] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

To determine whether multislice T1 mapping of the liver using a modified look-locker inversion recovery (MOLLI) sequence on gadoxetic acid-enhanced magnetic resonance imaging (MRI) can be used as a quantitative tool to estimate liver function and predict the presence of oesophageal or gastric varices. Phantoms filled with gadoxetic acid were scanned three times using MOLLI sequence to test repeatability. Patients with chronic liver disease or liver cirrhosis who underwent gadoxetic acid-enhanced liver MRI including MOLLI sequence at 3 T were included (n = 343). Pre- and postcontrast T1 relaxation times of the liver (T1liver), changes between pre- and postcontrast T1liver (Delta T1liver), and adjusted postcontrast T1liver (postcontrast T1liver-T1spleen/T1spleen) were compared among Child-Pugh classes. In 62 patients who underwent endoscopy, all T1 parameters and spleen sizes were correlated with varices. Phantom study showed excellent repeatability of MOLLI sequence. As Child-Pugh scores increased, pre- and postcontrast T1liver were significantly prolonged (P < 0.001), and Delta T1liver and adjusted postcontrast T1liver decreased (P < 0.001). Adjusted postcontrast T1liver and spleen size were independently associated with varices (R (2) = 0.29, P < 0.001). T1 mapping of the liver using MOLLI sequence on gadoxetic acid-enhanced MRI demonstrated potential in quantitatively estimating liver function, and adjusted postcontrast T1liver was significantly associated with varices. aEuro cent T1 mapping using MOLLI sequence can be achieved within a breath-hold. aEuro cent T1liver measured by MOLLI sequence provided excellent short-term repeatability. aEuro cent Precontrast and postcontrast T1liver were significantly prolonged as Child-Pugh scores increased. aEuro cent Adjusted postcontrast T1liver and spleen size were independently associated with varices.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据