Non-contact luminescence lifetime cryothermometry for macromolecular crystallography

期刊

JOURNAL OF SYNCHROTRON RADIATION
卷 24, 期 -, 页码 636-645

出版社

INT UNION CRYSTALLOGRAPHY
DOI: 10.1107/S1600577517003484

关键词

cryogenic thermometry; luminescence lifetime; protein crystalography; bismuth germanate (BGO)

资金

  1. Science and Technology Facility Council [ST/K002929]
  2. STFC [ST/K003046/1, ST/K002929/1, ST/N000447/1] Funding Source: UKRI
  3. Science and Technology Facilities Council [ST/K003046/1, ST/K002929/1, ST/N000447/1] Funding Source: researchfish

向作者/读者索取更多资源

Temperature is a very important parameter when aiming to minimize radiation damage to biological samples during experiments that utilize intense ionizing radiation. A novel technique for remote, non-contact, in situ monitoring of the protein crystal temperature has been developed for the new I23 beamline at the Diamond Light Source, a facility dedicated to macromolecular crystallography (MX) with long-wavelength X-rays. The temperature is derived from the temperature-dependent decay time constant of luminescence from a minuscule scintillation sensor (<0.05mm(3)) located in very close proximity to the sample under test. In this work the underlying principle of cryogenic luminescence lifetime thermometry is presented, the features of the detection method and the choice of temperature sensor are discussed, and it is demonstrated how the temperature monitoring system was integrated within the viewing system of the endstation used for the visualization of protein crystals. The thermometry system was characterized using a Bi4Ge3O12 crystal scintillator that exhibits good responsivity of the decay time constant as a function of temperature over a wide range (8-270K). The scintillation sensor was calibrated and the uncertainty of the temperature measurements over the primary operation temperature range of the beamline (30-150K) was assessed to be +/- 1.6K. It has been shown that the temperature of the sample holder, measured using the luminescence sensor, agrees well with the expected value. The technique was applied to characterize the thermal performance of different sample mounts that have been used in MX experiments at the I23 beamline. The thickness of the mount is shown to have the greatest impact upon the temperature distribution across the sample mount. Altogether, these tests and findings demonstrate the usefulness of the thermometry system in highlighting the challenges that remain to be addressed for the in-vacuum MX experiment to become a reliable and indispensable tool for structural biology.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据