4.2 Article Proceedings Paper

Design of a prototype split-and-delay unit for XFEL pulses, and their evaluation by synchrotron radiation X-rays

期刊

JOURNAL OF SYNCHROTRON RADIATION
卷 24, 期 -, 页码 95-102

出版社

INT UNION CRYSTALLOGRAPHY
DOI: 10.1107/S1600577516017744

关键词

split-and-delay unit; Bragg case interferometer; XFEL; synchrotron radiation X-rays

资金

  1. RIKEN
  2. Japan Atomic Energy Agency
  3. Grants-in-Aid for Scientific Research [26400327] Funding Source: KAKEN

向作者/读者索取更多资源

A prototype split-and-delay unit (SDU) for X-ray free-electron laser (XFEL) pulses is proposed based on the Graeff-Bonse four-Bragg-reflection interferometer by installing 12.5 degrees slopes. The SDU can continuously provide a delay time from approximately -20 to 40 ps with a resolution of less than 26 fs. Because the SDU was constructed from a monolithic silicon crystal, alignment is straightforward. The obtained thoroughputs of the SDU reached 0.7% at 7.46 keV and 0.02% at 14.92 keV. The tunability of the delay time using the proposed SDU was demonstrated by finding the interference effects of the split X-rays, and the time resolution of the proposed SDU was evaluated using the width of the interference pattern recorded on the X-ray charge-coupled device camera by changing the energy, i.e. longitudinal coherence length, of the incident X-rays. It is expected that the proposed SDU will be applicable to XFEL experiments using delay times from tens of femtoseconds to tens of picoseconds, e.g. intensity correlation measurements.