4.5 Article

Polarimetry at millimeter wavelengths with the NIKA camera: calibration and performance

期刊

ASTRONOMY & ASTROPHYSICS
卷 599, 期 -, 页码 -

出版社

EDP SCIENCES S A
DOI: 10.1051/0004-6361/201629666

关键词

ISM: magnetic fields; polarization; ISM: clouds; instrumentation: polarimeters

资金

  1. Foundation Nanoscience Grenoble
  2. LabEx FOCUS [ANR-11-LABX-0013]
  3. ENIGMASS French LabEx
  4. CNES post-doctoral fellowship program
  5. CNES doctoral fellowship program
  6. FOCUS French LabEx doctoral fellowship program
  7. European Research Council Advanced Grant ORISTARS under the European Union's Seventh Framework Programme [291294]
  8. STFC [ST/M001334/1, ST/N000706/1] Funding Source: UKRI
  9. Science and Technology Facilities Council [ST/N000706/1] Funding Source: researchfish

向作者/读者索取更多资源

Magnetic fields, which play a major role in a large number of astrophysical processes can be traced via observations of dust polarization. In particular, Planck low-resolution observations of dust polarization have demonstrated that Galactic filamentary structures, where star formation takes place, are associated to well organized magnetic fields. A better understanding of this process requires detailed observations of galactic dust polarization on scales of 0.01 to 0.1 pc. Such high-resolution polarization observations can be carried out at the IRAM 30 m telescope using the recently installed NIKA2 camera, which features two frequency bands at 260 and 150 GHz (respectively 1.15 and 2.05 mm), the 260 GHz band being polarization sensitive. NIKA2 so far in commissioning phase, has its focal plane filled with similar to 3300 detectors to cover a Field of View (FoV) of 6.5 arcmin diameter. The NIKA camera, which consisted of two arrays of 132 and 224 Lumped Element Kinetic Inductance Detectors (LEKIDs) and a FWHM (Full-Width-Half-Maximum) of 12 and 18.2 arcsec at 1.15 and 2.05 mm respectively, has been operated at the IRAM 30 m telescope from 2012 to 2015 as a test-bench for NIKA2. NIKA was equipped of a room temperature polarization system (a half wave plate (HWP) and a grid polarizer facing the NIKA cryostat window). The fast and continuous rotation of the HWP permits the quasi simultaneous reconstruction of the three Stokes parameters, I, Q, and U at 150 and 260 GHz. This paper presents the first polarization measurements with KIDs and reports the polarization performance of the NIKA camera and the pertinence of the choice of the polarization setup in the perspective of NIKA2. We describe the polarized data reduction pipeline, specifically developed for this project and how the continuous rotation of the HWP permits to shift the polarized signal far from any low frequency noise. We also present the dedicated algorithm developed to correct systematic leakage e ff ects. We report results on compact and extended sources obtained during the February 2015 technical campaign. These results demonstrate a good understanding of polarization systematics and state-of-the-art performance in terms of photometry, polarization degree and polarization angle reconstruction.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据