4.6 Article

Application of a bilayer tubular scaffold based on electrospun poly(L-lactide-co-caprolactone)/collagen fibers and yarns for tracheal tissue engineering

期刊

JOURNAL OF MATERIALS CHEMISTRY B
卷 5, 期 1, 页码 139-150

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c6tb02484j

关键词

-

资金

  1. National Natural Science Foundation of China [31470941, 31271035]
  2. Science and Technology Commission of Shanghai Municipality [15JC1490100, 15441905100]
  3. National Major Research Program of China [2016YFC1100200]
  4. PhD Programs Foundation of Ministry of Education of China [20130075110005]
  5. light of textile project [J201404]
  6. International Scientific Partnership Program ISPP at King Saud University (ISPP) [0049]

向作者/读者索取更多资源

A bilayer tubular scaffold (BLTS) consisting of poly(L-lactide-co-caprolactone) (P(LLA-CL))/collagen submicron sized fibers and micron sized yarns, was prepared via electrospinning. Then, autologous tracheal epithelial cells and chondrocytes were separately seeded onto the two layers of the BLTS. After culturing for 7 days, the cell-seeded BLTS (CS-BLTS) was implanted and wrapped in rat tracheal fascia for pre-vascularization. The pre-vascularized BLTS (PV-BLTS) was subjected to an in situ trachea regeneration study using a rat trachea injury model, along with CS-BLTS and bare BLTS for comparison. The results presented the bilayer structure of the BLTS, and the two layers were arranged conterminously. The porosity of the outer layer (collagen/P(LLA-CL) yarns) was found to be significantly higher (P < 0.05) than that of the inner layer (collagen/P(LLA-CL) fibers). In vitro biological analysis demonstrated that the collagen/P(LLA-CL) showed good biocompatibility, which promoted tracheal epithelial cell initial adhesion and proliferation with a highly significant difference (P < 0.001) or significant difference (P < 0.05) compared to those of pure P(LLA-CL) materials respectively. Chondrocyte activity and proliferation were also enhanced on collagen/P(LLA-CL) yarns with a significant difference (P < 0.05) compared to those of pure P(LLA-CL). Chondrocyte penetration was promoted as well, due to the loose and porous structure of the electrospun collagen/P(LLA-CL) yarns. The in vivo evaluation results of immune response analysis and histological investigation demonstrated that the PV-BLTS performed better in new capillary regeneration, reducing immunogenicity and improving tracheal tissue regeneration compared to the CS-BLTS and bare BLTS, indicating its promising potential as a new tissue engineered alternative for trachea repair and regeneration.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据