期刊
JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES
卷 10, 期 1, 页码 13-19出版社
TAYLOR & FRANCIS LTD
DOI: 10.1016/j.jrras.2015.01.002
关键词
Radionuclide; Uranium; Radiological risk; Toxicity; Laser
资金
- Board of Research in Nuclear Sciences (BRNS), Department of Atomic Energy (DAE), Government of India
In the present investigations, Laser Fluorimetry technique has been used for the microanalysis of uranium content in drinking water samples collected from different sources like the hand pumps, tube wells of various depths from wide range of locations in the four districts of SW-Punjab, India. The purpose of this study was to investigate the uranium concentration levels of ground water being used for drinking purposes and to determine its health effects, if any, to the local population of this region. Corresponding radiological and chemical risks have also been calculated for the uranium concentrations in ground water samples. Some other heavy elements have also been analysed using the Atomic Absorption Spectrometry. In this region, uranium concentration in 498 drinking water samples has been found to vary between 0.5 -579 mu gl(-1) with an average of 73.5 mu gl(-1). Data analysis revealed that 338 of 498 samples had uranium concentration higher than recommended safe limit of 30 mu gl(-1) (WHO, 2011) while 216 samples exceeded the threshold of 60 mu gl(-1) recommended by AERB, DAE, India, 2004. Copyright (C) 2015, The Egyptian Society of Radiation Sciences and Applications. Production and hosting by Elsevier B. V.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐