4.7 Article

Kinetics and energetics trade-off in reverse osmosis desalination with different configurations

期刊

DESALINATION
卷 401, 期 -, 页码 42-52

出版社

ELSEVIER
DOI: 10.1016/j.desal.2016.09.008

关键词

Reverse osmosis; Desalination; Energy consumption; Trade-off analysis

资金

  1. Bureau of Reclamation, Department of Interior, via DWPR [R15AC00088]

向作者/读者索取更多资源

Optimizing system design and operation of reverse osmosis (RO) systems requires an in-depth comprehension of the intrinsic tradeoff between RO mass transfer kinetics and energetics. In this study, we demonstrate that this critical trade-off can be quantified using the relationship between the average water flux and the specific energy consumption (SEC). We derive analytical expressions to quantify the average water flux and SEC for single stage, two stage, and closed circuit RO processes. These analytical expressions are useful for system design and operation optimization as they facilitate direct comparison of the kinetic and energetic efficiencies between RO processes with different operation conditions and system configurations. Finally, we compare the kinetics and energetics of the three system configurations using these analytical expressions and discuss their relative advantages and disadvantages in RO desalination. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据