4.5 Article

Non-rigid MR-TRUS image registration for image-guided prostate biopsy using correlation ratio-based mutual information

期刊

BIOMEDICAL ENGINEERING ONLINE
卷 16, 期 -, 页码 -

出版社

BMC
DOI: 10.1186/s12938-016-0308-5

关键词

Prostate; Needle biopsy; Non-rigid registration; CRMI; ISGD

资金

  1. National Key Research and Development Program of China [2016YFC0104500, 2016YFC0104505]
  2. Youth Innovation Promotion Association CAS [2014281]
  3. National Natural Science Foundation of China [61201117]
  4. Science and Technology Program of Suzhou [ZXY2013001]
  5. Shanghai Health and Family Planning Commission research projects [201540812]
  6. Shanghai Changhai Hospital New Medical Technology Breeding Program [NT201507]

向作者/读者索取更多资源

Background: To improve the accuracy of ultrasound-guided biopsy of the prostate, the non-rigid registration of magnetic resonance (MR) images onto transrectal ultrasound (TRUS) images has gained increasing attention. Mutual information (MI) is a widely used similarity criterion in MR-TRUS image registration. However, the use of MI has been challenged because of intensity distortion, noise and down-sampling. Hence, we need to improve the MI measure to get better registration effect. Methods: We present a novel two-dimensional non-rigid MR-TRUS registration algorithm that uses correlation ratio-based mutual information (CRMI) as the similarity criterion. CRMI includes a functional mapping of intensity values on the basis of a generalized version of intensity class correspondence. We also analytically acquire the derivative of CRMI with respect to deformation parameters. Furthermore, we propose an improved stochastic gradient descent (ISGD) optimization method based on the Metropolis acceptance criteria to improve the global optimization ability and decrease the registration time. Results: The performance of the proposed method is tested on synthetic images and 12 pairs of clinical prostate TRUS and MR images. By comparing label map registration frame (LMRF) and conditional mutual information (CMI), the proposed algorithm has a significant improvement in the average values of Hausdorff distance and target registration error. Although the average Dice Similarity coefficient is not significantly better than CMI, it still has a crucial increase over LMRF. The average computation time consumed by the proposed method is similar to LMRF, which is 16 times less than CMI. Conclusion: With more accurate matching performance and lower sensitivity to noise and down-sampling, the proposed algorithm of minimizing CRMI by ISGD is more robust and has the potential for use in aligning TRUS and MR images for needle biopsy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据