4.7 Article

An innovative structural and energy retrofitting system for URM walls using textile reinforced mortars combined with thermal insulation: Mechanical and fire behavior

期刊

CONSTRUCTION AND BUILDING MATERIALS
卷 133, 期 -, 页码 1-13

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.conbuildmat.2016.12.032

关键词

Energy retrofitting; Fire; Masonry; Out-of-plane bending; Seismic retrofitting; Textile reinforced mortar; Thermal insulation

资金

  1. European Commission, through the FP7 ITN project ENDURE

向作者/读者索取更多资源

The application of a new system, which combines textile reinforced mortars (TRM) and thermal insulating materials as a means of both structural (including seismic) and energy retrofitting of masonry walls is experimentally investigated in this study. Medium scale tests were carried out on 17 masonry walls subjected to out-of-plane bending. Several parameters were investigated, including the use of fire-resistant (cement-based) versus polymer-based insulating material, one sided versus two-sided insulation and/or TRM jacketing, placement of the TRM outside the insulation or in a sandwich form (over and under the insulation) and the displacement amplitude of the loading cycles. From the results obtained in this study the authors believe that TRM jacketing may be combined effectively with thermal insulation, which can be fire-resistant too. (C) 2016 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据