4.8 Article

Parametric study and performance evaluation of an organic Rankine cycle (ORC) system using low-grade heat at temperatures below 80 °C

期刊

APPLIED ENERGY
卷 189, 期 -, 页码 55-65

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2016.12.026

关键词

Organic Rankine cycle; Low-grade heat; Scroll expander; Parametric study; Performance map

资金

  1. Institute of Advanced Machinery and Design (IAMD) of Seoul National University
  2. BK plus program
  3. World Class University (WCU) program through the Korea Research Foundation [R31-2008-000-10083-0]
  4. Basic Science Research Program through the National Research Foundation of Korea (NRF) - Ministry of Science, ICT AMP
  5. Future Planning [2013R1A2A1A01014589]
  6. Korea Institute of Energy Technology Evaluation and Planning (KETEP) from the Ministry of Trade, Industry AMP
  7. Energy of Korea [20132010101780]
  8. National Research Foundation of Korea [2013R1A2A1A01014589] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

A parametric study and performance evaluation of an organic Rankine cycle (ORC) system that uses low-grade heat at a temperature below 80 degrees C and with a cycle power of less than 10 kW was undertaken to analyze the effects of the operating conditions on the performance and efficiency. R245fa was used as the working fluid, and a scroll expander as the power generation device. A model of the system was developed and its predictions were verified by the results of experiments, which were also used to determine the appropriate charge of the working fluid for maximizing the system power output. Owing to the difference between the variations of the power generated by the expander and the power consumed by the pump, the performance of the system was found to initially increase and then decrease with increasing refrigerant charge. The parametric investigation of the ORC system was conducted by varying the pressure ratio and mass flow rate of the working fluid. Increases in both parameters were found to increase the system performance by improving the torque generation and expander speed. The variation of the system performance with the heat sink temperature, which was varied between 20 and 35 degrees C, was also examined. The system power and efficiency were observed to decrease with increasing heat sink temperature owing to the decrease in the pressure ratio resulting from the increased condensation temperature. Based on the study findings, we propose a performance map for a low-temperature low-cycle-power ORC. The power and efficiency are shown to be proportional to the heat source temperature and capacity, which varies in a manner similar to the expander performance. The findings of this study highlight the feasibility of an ORC system that uses low-grade heat at a temperature below the boiling point. (C) 2016 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据