4.6 Article

Bioimpedance and Fluid Status in Children and Adolescents Treated With Dialysis

期刊

AMERICAN JOURNAL OF KIDNEY DISEASES
卷 69, 期 3, 页码 428-435

出版社

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1053/j.ajkd.2016.10.023

关键词

Hydration status; fluid status; body composition monitor (BCM); hemodialysis; peritoneal dialysis; pediatric; children; adolescents; multi-frequency bioimpedance measurement; total body water (TBW); extracellular water (ECW); body composition; stable isotopes; deuterium dilution; isotope ratio mass spectrometry; bromide dilution; fluid overload; renal failure

向作者/读者索取更多资源

Background: Assessment of hydration status in patients with chronic kidney failure treated by dialysis is crucial for clinical management decisions. Dilution techniques are considered the gold standard for measurement of body fluid volumes, but they are unfit for day-to-day care. Multifrequency bioimpedance has-been shown to be of help in clinical practice in adults and its use in children and adolescents has been advocated. We investigated whether application of multifrequency bioimpedance is appropriate for total-body water (TBW) and extracellular water (ECW) measurement in children and adolescents on dialysis therapy. Study Design: A study of diagnostic test accuracy. Setting & Participants: 16 young dialysis patients (before a hemodialysis session or after peritoneal dialysis treatment) from the Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy, and the Emma Children's Hospital Academic Medical Center, Amsterdam, the Netherlands. Index Test: TBW and ECW volumes assessed by multifrequency bioimpedance. Reference Tests: TBW and ECW volumes measured by deuterium and bromide dilution, respectively. Results: Mean TBW volumes determined by multifrequency bioimpedance and deuterium dilution were 19.2 +/- 8.7 (SD) and 19.3 +/- 8.3 L, respectively; Bland-Altman analysis showed a mean bias between the 2 methods of -0.09 (95% limits of agreement, -2.1 to 1.9) L. Mean ECW volumes were 8.9 +/- 4.0 and 8.3 +/- 3.3 L measured by multifrequency bioimpedance and bromide dilution, respectively; mean bias between the 2 ECW measurements was +0.6 (95% limits of agreement, -2.3 to 3.5). Limitations: Participants ingested the deuterated water at home without direct supervision by investigators, small number of patients, repeated measurements in individual patients were not performed. Conclusions: Multifrequency bioimpedance measurements were unbiased but imprecise in comparison to dilution techniques. We conclude that multifrequency bioimpedance measurements cannot precisely estimate TBW and ECW in children receiving dialysis. (C) 2016 by the National Kidney Foundation, Inc.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据