Image-guided implantation of the Bonebridge™ with a surgical navigation: A feasibility study

期刊

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.ijscr.2016.11.057

关键词

Bonebridge; Surgical navigation; 3D simulation software program; Temporal bone

类别

资金

  1. National Research Foundation of Korea (NRF) grant - Korea government (MSIP) [2015R1C1A1A02036354]
  2. Ministry of Trade, Industry & Energy(MOTIE, Korea) under Industrial Strategic Technology Development Program [10051518]
  3. Korea Evaluation Institute of Industrial Technology (KEIT) [10051518] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  4. National Research Foundation of Korea [2015R1C1A1A02036354] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

OBJECTIVE: To access a method of fitting a designated location on the patient's temporal bone by surgically navigating to the Bonebridge implantation. STUDY DESIGN: A patient with unilateral profound hearing loss received early intervention with the Bonebridge implant for binaural hearing. The optimal implant site was determined from computed tomography (CT) images using a three-dimensional (3D) simulation software program before the surgery. The pre-calculated coordinates from the 3D simulation software program were moved to the Scopis Hybrid Navigation System. After using the surgical navigation system for the surgery, we evaluated the degree of mismatch of the center of the bone conduction-floating mass transducer (BC-FMT) between the computer simulation and the actual drilling. ESULTS: The time required to determine the implant location on the surface of the patient's temporal bone was shortened, and the accuracy of the implantation was high. The coordinates on the 3D simulation system were comparable to the surgical navigation system. The predicted coordinates were replicated exactly upon actual drilling during the surgery, and we could confirm this in preoperative and postoperative images. CONCLUSIONS: Using an image-guided surgical navigation system to aid in the placement of the BC-FMT on the simulated location is a simple procedure and is more effective that finding the exact coordinates. It also shortens the decision time for applying the implant. (C) 2016 The Author(s). Published by Elsevier Ltd on behalf of IJS Publishing Group Ltd. This is an open access article under the CC BY-NC-ND license