4.8 Article

Detecting circulating antibodies by controlled surface modification with specific target proteins: Application to malaria

期刊

BIOSENSORS & BIOELECTRONICS
卷 91, 期 -, 页码 833-841

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2017.01.031

关键词

Biosensor; Immune response detection; Antibodies; Malaria; Electrochemical measurements

资金

  1. Swiss National Science Foundation [31003A_149925]
  2. G.C.M. acknowledges CNPq (Conselho Nacional de Desenvolvimento Cientifico e Tecnologico
  3. Wellcome Trust career development fellowship [097395/Z/11/Z]
  4. Jenner Investigator
  5. Wellcome Trust [097395/Z/11/Z] Funding Source: Wellcome Trust
  6. Swiss National Science Foundation (SNF) [31003A_149925] Funding Source: Swiss National Science Foundation (SNF)

向作者/读者索取更多资源

Sensitive detection of specific antibodies by biosensors has become of major importance for monitoring and controlling epidemics. Here we report a development of a biosensor able to specifically measure antibodies in a drop of unmodified blood serum. Within minutes, the detection system measures presence of antibodies against Plasmodium vivax, a causing agent for malaria. The biosensor consists of a layer of carbon nanotubes (CNTs) which were casted on a carbon working electrode area of a three-electrode system and oxidized. An amine layer was produced next by modifying the surface with EDAC/NHS followed by reaction with a diamine compound. Finally, the protein fragments derived from P.vivax containing well-known antigen sequences were casted on this layer and bound through electrostatic interactions, involving hydrogen and ionic bonding. All these chemical changes occurring at the carbon surface along the biosensor assembly were followed and confirmed by Fourier Transformed Infrared s pectrometry (FIIR) and Raman spectroscopy. The presence of antibodies in serum was detected by monitoring the electrical properties of the layer, making use of cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV), against a standard iron probe. Overall, the charge-transfer resistance decreased after antibody binding, because there was an additional amount of protein bound to the surface. This hindered the access of the iron redox probe to the conductive support at the electrode surface. Electrical changes could be measured at antibody concentration as low as similar to 6-50 pg/L (concentrations in the range of 10-15 M) and as high as similar to 70 mu g/L. Specific measurement with low background was even possible in undiluted serum. Hence, this novel biosensor allows assessing serum antibody levels in real time and in un-manipulated serum samples on-site where needed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据