4.2 Article

Intraoperative factors associated with stranded source placement accuracy in low-dose-rate prostate brachytherapy

期刊

BRACHYTHERAPY
卷 16, 期 3, 页码 497-502

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.brachy.2017.01.007

关键词

Prostate; Brachytherapy; Low dose rate; Misplacement; Intraoperative factors; Transrectal ultrasound

资金

  1. Alberta Cancer Foundation
  2. Alberta Innovates Health Solutions [26712]
  3. Canadian Institute for Health Research
  4. Best Medical
  5. Alberta Innovates [201201232] Funding Source: researchfish

向作者/读者索取更多资源

PURPOSE: The quality of a low dose rate prostate brachytherapy implant depends on the accurate placement of sources in their planned locations. This study investigates intraoperative factors that potentially contribute to stranded source placement inaccuracy in prostate brachytherapy. METHODS AND MATERIALS: Intraoperative video images of the brachytherapist's hand motions and needle insertions during the implant procedure were acquired for analysis. Using video analysis software, maximum and average needle insertion velocities were determined. The number of needle insertion attempts and the use of the brachytherapist's other hand to manipulate the needle direction were also recorded. Sources misplacements were analyzed using an ultrasound-based method described elsewhere. RESULTS: Fifteen patients agreed to undergo this study; 1619 1251 seeds were inserted using 357 needles; 1197 seeds were confidently identified using ultrasound images and included in the analysis. The mean overall misplacement was 0.49 cm (0-2 cm, 95% CI = 0.47-0.51); 614 seeds were delivered with a single pass and 583 seeds with > 1 passes (range 2-6). The mean maximum needle velocity was 12.34 cm s(-1) (range 4-28 cm s(-1)) and mean average velocity was 4.76 cm s(-1) (range 0.4-17.4 cm s(-1)); 747 seeds were delivered with manipulation of the needle. The generalized linear model test was used to analyze factors contributing to seed misplacement, and it was found that a maximum speed < 12 cm s(-1) was associated with a decrease in seed misplacement by 0.049 cm vs. a maximum speed > 12 cm s(-1,) p = 0.0121). Other evaluated factors were found to have no statistically significant correlation with seed misplacement: average speed (p = 0.4947), manual manipulation of needle (p = 0.9264), and number of needle passes (p = 0.8907). CONCLUSIONS: This study identified that needles inserted with lower maximum velocity were associated with less seed misplacement. Manual manipulation of the needle, number of passes, and average speed did not show statistically significant correlation with seed misplacement. (C) 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据