4.8 Article

Femtomolar detection of cardiac troponin I using a novel label-free and reagent-free dendrimer enhanced impedimetric immunosensor

期刊

BIOSENSORS & BIOELECTRONICS
卷 91, 期 -, 页码 637-643

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2017.01.021

关键词

Impedimetric immunosensor; Dendrimer, 3, 3 ', 5, 5 '-Tetramethylbenzidine; Protein biomarkers; Cardiac troponin I; Human serum

资金

  1. Basic Research Program [2015R1D1A1A01056721]
  2. National Research Foundation, Korean Government (MSIP)
  3. NAP project of the Korea Basic Science Institute [T35780]

向作者/读者索取更多资源

A novel highly sensitive dendrimer coupled impedimetric immunosensor was developed for the label-free and reagent-free detection of cardiac troponin I (TnI) in serum samples. The immunosensor probe was fabricated by covalently attaching carboxylic acid-functionalized third generation (G3) poly (amidoamine) (PAMAM) dendrimer (Den) on the 3, 3', 5, 5'-tetramethyl benzidine (TMB) modified 6-mercaptohexanoic acid (MHA) self-assembled monolayer (SAM) on a gold (Au) electrode. Monoclonal anti-TnI antibody was then covalently immobilized on the Den and TMB attached MHA SAM modified surface. TMB was used as an internal surface redox couple for generating signal which also allowed to avoid the use of an external one (i.e. ferricyanide couple) in solution during the impedance measurement for monitoring the antibody-antigen binding. On the other hand, Den was used as a signal enhancer by immobilizing more anti-body on the immunosensor probe. The immunosensor probe was characterized using X-ray photoelectron spectroscopy (XPS), quartz crystal microbalance (QCM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) techniques. The TnI detection in diluted serum was based on the measurement of charge transfer resistance (R-ct) of the electron transfer process of the surface -attached TMB before and after immunobinding. Under the optimized condition, the proposed immunosensor could detect human TnI in diluted serum samples as low as 11.7 fM with a wide linear dynamic range, good stability, and excellent specificity. The validity of the proposed method was tested in various TnI spiked human undiluted serum samples and was compared with the enzyme -linked immunosorbent assay (ELISA). The results suggested that the proposed immunosensor could be a useful tool for practical applications in clinical diagnosis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据