4.8 Article

Signal-On Photoelectrochemical Immunoassay for Aflatoxin B1 Based on Enzymatic Product-Etching MnO2 Nanosheets for Dissociation of Carbon Dots

期刊

ANALYTICAL CHEMISTRY
卷 89, 期 10, 页码 5637-5645

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.7b00942

关键词

-

资金

  1. National Natural Science Foundation of China [21475025, 21675029]
  2. National Science Foundation of Fujian Province [2014J07001]
  3. Program for Changjiang Scholars and Innovative Research Team in University [IRT15R11]
  4. Alexander von Humboldt Foundation of Germany

向作者/读者索取更多资源

Aflatoxin B-1 (AFB(1)) monitoring has attracted extensive attention because food safety is a worldwide public health problem. Herein, we design a novel simultaneously visual and photoelectrochemical (PEC) immunosensing system for rapid sensitive detection of AFB(1) in foodstuff The immunoreaction was carried out on anti-AFB, antibody-modified magnetic beads by using glucose oxidase (GOX)-labeled AFB(1-)bovine serum albumin (AFB(1)-BSA) conjugates as the tags with a competitive-type immunoassay format, while the visual and PEC evaluation was performed via carbon quantum dots (CQDs)-functionalized MnO2 nanosheets. Accompanying, the formation of immunocomplexes, the carried GOx initially oxidized the substrate (glucose) for the generation of H2O2, which reduced/etched MnO2 nanosheets into Mn2+-ions, thereby resulting in the dissociation of CQDs from the electrode. Within the applied potentials, the photocurrent of MnO(2-)CQDs-modified electrode decreased with the increasing H2O2 level in the detection cell. Meanwhile, a visual detection could be performed according to the change in the color of MnO2-CQDs-coated electrode. To elaborate, this system was aggregated into a high -throughput microfluidic device to construct a semiautomatic detection cell. Under optimal conditions, the photocurrent increased with the increasing target AFB1 within a dynamic working range from 0.01 to 20 ng mL(-1) with a limit of detection (LOD) of 2.1 pg mL(-1) (ppt). The developed immunoassay exhibited good reproducibility and acceptable accuracy. In addition, the method accuracy relative to AFB1 ELISA kit was evaluated for analyzing naturally contaminated or spiked peanut samples, giving the well-matched results between two methods. Although our strategy-was focused on the detection of target AFB1, it is easily extended to screen other small molecules or mycotoxins, thereby representing a versatile immunosensing scheme.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据