4.8 Article

Kinetic Requirements for Spatiotemporal Chemical Imaging with Fluorescent Nanosensors

期刊

ACS NANO
卷 11, 期 4, 页码 4017-4027

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acsnano.7b00569

关键词

chemical imaging; single-molecule methods; biosensors; fluorescence microscopy; kinetics; simulations; signaling

资金

  1. Fonds der chemischen Industrie (FCI)
  2. state of Lower Saxony (life@nano)
  3. Cluster of Excellence
  4. DFG Research Center Nanoscale Microscopy and Molecular Physiology of the Brain

向作者/读者索取更多资源

Fluorescent nanosensors are powerful tools for basic research and bioanalytical applications. Individual nanosensors are able to detect single molecules, while ensembles of nanosensors can be used to measure the bulk concentration of an analyte. Collective imaging of multiple nanosensors could provide both spatial and temporal chemical information from the nano- to the microscale. This type of chemical imaging with nanosensors would be very attractive to study processes such as chemical signaling between cells (e.g., neurons). So far, it is not understood what processes are resolvable (concentration, time, space) and how optimal sensors should be designed. Here, we develop a theoretical framework to simulate the fluorescence image of arrays of nanosensors in response to a concentration gradient. For that purpose, binding and unbinding of the analyte is simulated for each single nanosensor by using a Monte Carlo simulation and varying rate constants (k(on), k(off)). Multiple nanosensors are arranged on a surface and exposed to a concentration pattern c(A)(x,y,t) of an analyte. We account for the resolution limit of light microscopy (Abbe limit) and the acquisition speed and resolution of optical setups and determine the resulting response images Delta I(x,y,t). Consequently, we introduce terms for the spatial and temporal resolution and simulate phase diagrams for different rate constants that allow us to predict how a sensor should be designed to provide a desired spatial and temporal resolution. Our results show, for example, that imaging of neurotransmitter release requires rate constants of k(on) = 10(6) M-1 s(-1) and k(off) = 10(2) s(-1) in many scenarios, which corresponds to high dissociation constants of K-d > 100 mu M. This work predicts if a given fluorescent nanosensor array (rate constants, size, shape, geometry, density) is able to resolve fast concentration changes such as neurotransmitter release from cells. Additionally, we provide rational design principles to engineer nanosensors for chemical imaging.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据