4.7 Article

The impacts of building height variations and building packing densities on flow adjustment and city breathability in idealized urban models

期刊

BUILDING AND ENVIRONMENT
卷 118, 期 -, 页码 344-361

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2017.03.042

关键词

City breathability; Flow adjustment; Exchange velocity; Building height variation; Computational fluid dynamics (CFD); simulation; Wind tunnel

资金

  1. National Natural Science Foundation of China [51478486, 41622502]
  2. National Science Fund for Distinguished Young Scholars [41425020]
  3. Fundamental Research Funds for the Central Universities [161gzd01]
  4. Science and Technology program of Guangzhou, China [201607010066]

向作者/读者索取更多资源

Improving city breathability has been confirmed as one feasible measure to improve pollutant dilution in the urban canopy layer (UCL). Building height variability enhances vertical mixing, but its impacts remain not completely explored. Therefore, both wind tunnel experiments and computational fluid dynamic (CFD) simulations are used to investigate the effect of building height variations (six height standard deviations sigma(H) = 0%-77.8%) associated to building packing densities namely lambda(p)/lambda(f) = 0.25/0.375 (medium-density) and 0.44/0.67 (compact) on city breathability. Two bulk variables (i.e. the in-canopy velocity (U-C and exchange velocity (U-E)) are adopted to quantify the horizontal and vertical city breathability respectively, which are normalized by the reference velocity (U-ref) in the free flow, typically set at z = 2.5H(0) where H-0 is the mean building height. Both flow quantities and city breathability experience a flow adjustment process, then reach a balance. The adjustment distance is at least three times longer than four rows documented in previous literature. The medium-density arrays experience much larger U-C and U-E than the compact ones. U-E is found mainly induced by vertical turbulent fluxes, instead of vertical mean flows. In height-variation cases, taller buildings experience larger drag force and city breathability than lower buildings and those in uniform-height cases. For medium-density and compact models with uniform height, the balanced U-C/U-ref are 0.124 and 0.105 respectively, moreover the balanced U-E/U-ref are 0.0078 and 0.0065. In contrast, the average U-C/U-ref in height-variation cases are larger (115.3%-139.5% and 125.7%-141.9% of uniform-height cases) but U-E/U-ref are smaller (74.4%-79.5% and 61.5%-86.2% of uniform-height cases) for medium-density and compact models. (C) 2017 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据