4.6 Article

Electrochemical Sensor Constructed Using a Carbon Paste Electrode Modified with Mesoporous Silica Encapsulating PANI Chains Decorated with GNPs for Detection of Ascorbic Acid

期刊

ELECTROCHIMICA ACTA
卷 238, 期 -, 页码 246-256

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.electacta.2017.04.021

关键词

electroactive; polyaniline; mesoporous; gold; ascorbic acid; sensor

资金

  1. Ministry of Science and Technology, Taiwan, R.O.C [MOST 104-2113-M-033001-MY3, MOST 104-2923-M-033-001-MY2]
  2. Department of Chemistry, Center for Nanotechnology at ChungYuan Christian University
  3. Department of Science and Technology (Philippines), and University of Santo Tomas

向作者/读者索取更多资源

In this work, an electrochemical sensor constructed using a carbon paste electrode (CPE), modified with mesoporous silica encapsulating polyaniline (PANI) decorated with gold nanoparticles (GNPs) for the detection of ascorbic acid (AA), was presented. First of all, PANI latex was synthesized by emulsion polymerization. Then, the acid-catalyzed sol-gel solutions of tetraethyl silicate (TEOS) was prepared in the presence of D-glucose, followed by encapsulation of previously prepared PANI latex into as-prepared sol-gel solution. Upon formation of silica frameworks, electroactive composite powder was obtained. Subsequently, the as-prepared composite powder was subjected to Soxhlet extraction to remove D-glucose and the final product was denoted as PM silica. On the other hand, PGM silica was obtained by immersing PM silica in 5 mL of 0.10 mM HAuCl4 solution for 6 h, which reduced the gold nanoparticles (GNPs) onto the surface of PANI chains located inside the nanochannels of wormhole-like mesoporous silica framework. The redox reactions that mediated between EB form of PANI and aqueous HAuCl4 solution were monitored and confirmed by FTIR spectra. The appearance of GNPs inside the PGM silica was characterized by TEM, XPS, XRD, and BET analyses. PGM silica was found to reveal higher redox capability as compared to that of PM silica based on the electrochemical CV studies. It should be noted that PGM silica-modified CPE was found to exhibit high sensitivity, a relatively low limit of detection, excellent sensing repeatability and a broader linear dynamic range for AA detection than those of bare CPE or PM silica-modified CPE. Moreover, A electrochemical sensor constructed from PGM silica-modified CPE was found to reveal better selectivity for a tertiary mixture of AA/DA/UA as compared to that of PM silica-modified CPE based on a series of studies of differential pulse voltammograms. In this work, the fabricated sensor showed reliable data in detecting AA in the tested commercially available products. (C) 2017 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据