4.7 Article

Development of aflatoxin B1 aptasensor based on wide-range fluorescence detection using graphene oxide quencher

期刊

COLLOIDS AND SURFACES B-BIOINTERFACES
卷 154, 期 -, 页码 27-32

出版社

ELSEVIER
DOI: 10.1016/j.colsurfb.2017.03.010

关键词

Aflatoxin B1; Molecular detection; Fluorescence quenching; Graphene oxide

资金

  1. Advanced Production Technology Development Program, Ministry of Agriculture, Food and Rural Affairs [315050-2]
  2. Chung-Ang University
  3. Institute of Planning & Evaluation for Technology in Food, Agriculture, Forestry & Fisheries (iPET), Republic of Korea [315050022SB010] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  4. National Research Council of Science & Technology (NST), Republic of Korea [E0152200-03] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  5. National Research Foundation of Korea [22A20130012543, 22A20153613139] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

Aflatoxin B-1 (AFB(1)) is a carcinogenic substance produced by fungi of genus Aspergillus, especially Aspergillus flavus. Few nanograms of AFB(1) that permeated through the skin is sufficient to cause liver cancer and stunted growth. In this study, a rapid aptamer-based assay for AFB(1) was developed using the fluorescence quenching property of graphene oxide (GO) and a fluorescein amidite (FAM)-modified aptamer specific to AFB(1). The aptamer, modified with the fluorescence dye FAM on its 5'-end, was used as a probe. Once bound by AFB(1), a conformational change of the aptamer was caused that led to its interaction with the well-known fluorescence quencher GO, resulting in a decrease of the fluorescence intensity of the system. In the absence of AFB(1), the fluorescence intensity remained unchanged. The aptamer-based AFB(1) assay process was conducted through 3 steps within 40 min. The aptamer was incubated with AFB(1) before the addition of GO. The amount of AFB(1) present was measured by the change in fluorescence intensity. The detection system was evaluated with standard solutions of AFB(1) of various concentrations. The results showed that the fluorescence intensity decreased linearly as the concentration of AFB(1) gradually increased. Although the assay was specific to AFB(1), there was slight interference by other types of aflatoxin. When the assay was applied to a real sample, the limit of detection was 4.5 ppb, which was within the wide detection range of up to 300 ppb with good linearity. Thus, this biosensor is considered to be competitive with the conventional detection methods in the field owing to its wide detection range and assay rapidity. (C) 2017 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据