4.7 Article

A comparative study of the performance of solar ponds under Middle Eastern and Mediterranean conditions with batch and continuous heat extraction

期刊

APPLIED THERMAL ENGINEERING
卷 120, 期 -, 页码 728-740

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2017.03.086

关键词

Solar pond model; Salinity gradient; Transient heat transfer; Heat extraction; Solar thermal engineering; Renewable energy

资金

  1. Department of Chemical and Process Engineering at the University of Surrey

向作者/读者索取更多资源

This study presents a novel heat extraction method, which can be operated in batch or continuous, modes for salinity gradient solar ponds. A comparison between the performance of two solar ponds of the same size (10,000 m(2)) in Adana (Turkey) and Ahvaz (Iran) is also presented. The heat extraction method entails brine removal from the non-convective zone (NCZ) as well as the heat storage zone (HSZ). The presented model incorporates the heat losses from the bottom and surface of the pond as well as the cooling effect imposed as a consequence of the replacement of extracted brine from each layer, and the supply of freshwater to the surface of the pond to maintain its inventory. The model can be employed to predict the performance of solar ponds of various dimensions for any given location. It was established that the pond modelled for Ahvaz would perform 30% better than the pond in Adana in both batch and continuous heat extraction modes, predominantly due to the higher quantities of solar energy reaching the surface of the pond and the higher air temperatures throughout the year at this location. The quantities of heat provided in the first year of operation from the ponds in Adana and Ahvaz in batch mode extraction are 2.8 x 10(6) MJ and 4.0 x 10(6) MJ, respectively. These values are approximately three times higher than those from the continuous mode of heat extraction due to the larger volume of withdrawal in the batch mode. Using the proposed heat extraction method in batch mode, 85% of the total heat is removed from the HSZ while this is just over 50% for the continuous mode indicating the better energy storage performance of the batch mode. Both heat extraction modes offer an efficient mechanism of stabilising a temperature gradient throughout the pond with the aim of insulating the HSZ for heat storage. This is carried out by designating brine removal thresholds of 70 degrees C, 80 degrees C and 90 degrees C within the NCZ and 95 degrees C in the HSZ. It is also demonstrated that the requirement for the supply of freshwater to the surface of solar ponds is significantly dependant on the wind velocity at each location and is unaffected by the mode of heat extraction. (C) 2017 Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据