4.7 Article

Amino-silica/graphene oxide nanocomposite coated cotton as an efficient sorbent for needle trap device

期刊

ANALYTICA CHIMICA ACTA
卷 975, 期 -, 页码 11-19

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2017.04.031

关键词

Cotton/grapheneoxide/amino-silica nanocomposite; Needle trap device; PAHs; Soil; GC-FID

向作者/读者索取更多资源

Cotton and silica are easily available and plentiful natural materials, with significant sorptive properties, which can be provided easily at low prices. In this research, a novel and effective sorbent was synthesized by covalent attachment of amino-silica/graphene oxide nanocomposite to the cotton (Cot/GO/Si) and packed into a stainless steel needle for preparation a needle trap device (NTD). The nanocomposite sorbent was characterized by SEM and FT-IR. The Cot/GO/Si packed NTD was used for direct extraction of PAHs from polluted soil samples, followed by GC-FID measurement. Different affecting experimental variables, including extraction temperature, flow rate, desorption time and temperature were studied and optimized. Under the optimal conditions, good linearity of the calibration curves (R-2 > 0.99) was obtained over the concentration range of 0.01-1.0 mu g g(-1). The limits of detection, limits of quantification and relative standard deviations were found to be in the ranges of 0.05-0.17 ng g(-1), 0.2-0.6 ng g(-1) and 9.7-15.4% (n = 6), respectively. Finally, the proposed NTD-GC-FID method was successfully applied for the extraction and determination of PAHs in contaminated soil samples. (C) 2017 Elsevier B.V. All rights reserved.