4.7 Article

Increasing Number of Passes Beyond 4 Does Not Increase Sensitivity of Detection of Pancreatic Malignancy by Endoscopic Ultrasound-Guided Fine-Needle Aspiration

期刊

CLINICAL GASTROENTEROLOGY AND HEPATOLOGY
卷 15, 期 7, 页码 1071-+

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.cgh.2016.12.018

关键词

Endoscopic Ultrasonography; Fine-Needle Aspiration; Pancreatic Cancer; Cytopathology

资金

  1. American College of Gastroenterology Clinical Research Award [ACGCR-006-2011]

向作者/读者索取更多资源

BACKGROUND & AIMS: It is not clear exactly how many passes are required to determine whether pancreatic masses are malignant using endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). We aimed to define the per-pass diagnostic yield of EUS-FNA for establishing the malignancy of a pancreatic mass, and identify factors associated with detection of malignancies. METHODS: In a prospective study, 239 patients with solid pancreatic masses were randomly assigned to groups that underwent EUS-FNA, with the number of passes determined by an on-site cytopathology evaluation or set at 7 passes, at 3 tertiary referral centers. A final diagnosis of pancreatic malignancy was made based on findings from cytology, surgery, or a follow-up evaluation at least 1 year after EUS-FNA. The cumulative sensitivity of detection of malignancy by EUS-FNA was calculated after each pass; in the primary analysis, lesions categorized as malignant or suspicious were considered as positive findings. RESULTS: Pancreatic malignancies were found in 202 patients (84.5% of the study population). EUS-FNA detected malignancies with 96% sensitivity (95% confidence interval [CI], 92%-98%); 4 passes of EUS-FNA detectedmalignancies with 92% sensitivity (95% CI, 87%-95%). Tumor size greater than 2 cm was the only variable associated with positive results from cytology analysis (odds ratio, 7.8; 95% CI, 1.9-31.6). In masses larger than 2 cm, 4 passes of EUS-FNA detected malignancieswith 93% sensitivity (95% CI, 89%-96%) and in masses <= 2 cm, 6 passes was associated with 82% sensitivity (95% CI, 61%-93%). Sensitivity of detection did not increase with increasing number of passes. CONCLUSIONS: In a prospective study, we found 4 passes of EUS-FNA to be sufficient to detect malignant pancreatic masses; increasing the number of passes did not increase the sensitivity of detection. Tumor size greater than 2 cm was associated with malignancy, and a greater number of passes may be required to evaluate masses 2 cm or less.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据