4.7 Article

Molecularly imprinted polymers based stir bar sorptive extraction for determination of cefaclor and cefalexin in environmental water

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 409, 期 17, 页码 4157-4166

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-017-0365-z

关键词

Molecularly imprinted polymers; Magnetic carbon nanotubes; Cephalosporins; Environmental water; Stir bar sorption microextraction

资金

  1. Chinese College Students Innovation Project for the R&D of Novel Drugs [J1310032]
  2. Jiangsu Province Environmental Protection Scientific Research Subject and Science and Technology Project-Nanotechnology Special of Suzhou Municipal Science and Technology Bureau [ZX201441]

向作者/读者索取更多资源

Although stir bar sportive extraction was thought to be a highly efficiency and simple pretreatment approach, its wide application was limited by low selectivity, short service life, and relatively high cost. In order to improve the performance of the stir bar, molecular imprinted polymers and magnetic carbon nanotubes were combined in the present study. In addition, two monomers were utilized to intensify the selectivity of molecularly imprinted polymers. Fourier transform infrared spectroscopy, scanning electron microscopy, and selectivity experiments showed that the molecularly imprinted polymeric stir bar was successfully prepared. Then micro-extraction based on the obtained stir bar was coupled with HPLC for determination of trace cefaclor and cefalexin in environmental water. This approach had the advantages of stir bar sportive extraction, high selectivity of molecular imprinted polymers, and high sorption efficiency of carbon nanotubes. To utilize this pretreatment approach, pH, extraction time, stirring speed, elution solvent, and elution time were optimized. The LOD and LOQ of cefaclor were found to be 3.5 ng center dot mL(-1) and 12.0 ng center dot mL(-1), respectively; the LOD and LOQ of cefalexin were found to be 3.0 ng center dot mL(-1) and 10.0 ng center dot mL(-1), respectively. The recoveries of cefaclor and cefalexin were 86.5 similar to 98.6%. The within-run precision and between-run precision were acceptable (relative standard deviation < 7%). Even when utilized in more than 14 cycles, the performance of the stir bar did not decrease dramatically. This demonstrated that the molecularly imprinted polymeric stir bar based micro-extraction was a convenient, efficient, low-cost, and a specific method for enrichment of cefaclor and cefalexin in environmental samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据