4.8 Article

Tilted membrane panel: A new module concept to maximize the impact of air bubbles for membrane fouling control in microalgae harvesting

期刊

BIORESOURCE TECHNOLOGY
卷 241, 期 -, 页码 661-668

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.biortech.2017.05.175

关键词

Tilted panel; Microalgae harvesting; Membrane photobioreactor; Membrane fouling; Air bubbles

资金

  1. Universiti Teknologi Petronas - Malaysia [0153AA-F58, 0153AA-F59]

向作者/读者索取更多资源

Microalgae harvesting using membrane technology is challenging because of its high fouling propensity. As an established fouling mitigation technique, efficacy of air bubbles can be improved by maximizing the impact of shear-rates in scouring foulant. In this study, it is achieved by tilting the membrane panel. We investigate the effect of tilting angle, switching period as well as aeration rate during microalgal broth filtration. Results show that higher tilting angles (up to 20 degrees) improve permeability of up to 2.7 times of the vertical panel. In addition, operating a one-sided panel is better than a two-sided panel, in which the later involved switching mode. One-sided membrane panel only require a half of area, yet its performance is comparable with of a large-scale module. This tilted panel can lead to significant membrane cost reductions and eventually improves the competitiveness of membrane technology for microalgae harvesting application. (C) 2017 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。