4.6 Article

Seismic Performance Evaluation of Asymmetric Reinforced Concrete Tunnel Form Buildings

期刊

STRUCTURES
卷 10, 期 -, 页码 157-169

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.istruc.2017.03.005

关键词

Reinforced concrete tunnel form structures; Response modification factor; Asymmetric plan; Incremental dynamic analysis; Performance based earthquake engineering

向作者/读者索取更多资源

Despite the excellent seismic resistance characteristics of reinforced concrete tunnel form(RCTF) buildings, their predominant torsional vibration modes, especially those related to asymmetric RCTF constructions, make them vulnerable to strong seismic ground motions. For this reason, design guidelines prohibit the construction of multi-story RCTF buildings with asymmetric plans. This lack of relevant code provisions in turn, forces the engineer to apply designmethods relevant to typical reinforced concrete (RC) buildings despite the well-known differences in the seismic performance when compared to RCTF buildings. This issue becomes more challenging when one is interested in asymmetric RCTF buildings whose past seismic performance is generally unknown. The present study investigates the seismic performance of two-, five-, and fifteen-story asymmetric RCTF buildings with two distinct plans. A number of parameters such as the percentage of walls at each story level and the in-plan eccentricity, on the lateral capacity of the building subjected to strong ground motions are highlighted. The effect of coupling beams (spandrels) on performance of RCTF constructions is also examined. It is concluded that they do not generally contribute in strength and ductility of low height constructions and in taller ones; due to inducing more demands, these low strength shear-failure-type members fail prematurely. However, if these elements are designed based on building code requirements and implemented with adequate shear reinforcements, they may be used as the structural fuses for dissipating seismic energy. The multilevel performance-based response modification factor (R-factor) is considered in order to capture the seismic performance of the RCTF structures. Relevant demand/supply R-factors are determined for this particular case study involving all the effective parameters such as ductility, over-strength, redundancy, seismic hazard level, and performance level. As a general conclusion, the results of the research show an excellent seismic performance of this type of structures in spite of their inherent irregularities. The high lateral stiffness and strength of the RCTF building compensates for the relatively low torsional stiffness with respect to lateral stiffness; as a result of which, the building exhibits superior seismic performance in high seismic hazard regions. (C) 2017 Institution of Structural Engineers. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据