期刊
BIOCHEMICAL ENGINEERING JOURNAL
卷 124, 期 -, 页码 6-12出版社
ELSEVIER
DOI: 10.1016/j.bej.2017.04.005
关键词
Sulfide removal; Nitrogen removal; Power recovery; Buffer; Hydraulic retention time; Temperature
资金
- National Natural Science Foundation of China [21577108]
A novel denitrifying sulfide removal microbial fuel cell (MFC), using sulfide and nitrate separately as the anodic electron donor and the cathodic electron acceptor, was explored to recover power coupled with pollutants removal. Power recovery coupled with sulfide and nitrate removal in this MFC was achieved under different buffers, hydraulic retention times (HRT5) and temperatures. Bicarbonate was deemed as a suitable alternative buffer to phosphate in this MFC, obtaining comparable power recovery and pollutant removal loadings but without potential secondary pollution. Shortening HRT from 5.54 h to 2.27 h or increasing temperature from 20 degrees C to 30 degrees C favored both power recovery and pollutants removal. The suitable HRT and temperature for this MFC were found to be 2.77 h and 30 degrees C, achieving a power density of 2.80 +/- 0.05 W/m(3) NC, a sulfide removal loading of 1.07 +/- 0.03 kg S/(m(3) NC.d), and a nitrate removal loading of 14.4 +/- 0.3 gN/(m(3) NC.d). Shortening HRT and lowering temperature would be beneficial to suppress sulfate formation, but more than 71.9% of sulfide was oxidized to sulfate in current study. (c) 2017 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐