4.6 Article

Full-length antibodies versus single-chain antibody fragments for a selective impedimetric lectin-based glycoprofiling of prostate specific antigen

期刊

ELECTROCHIMICA ACTA
卷 246, 期 -, 页码 399-405

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.electacta.2017.06.065

关键词

impedimetric biosensors; full-length antibodies; single-chain antibody fragments (scAb); lectins; glycan analysis; prostate cancer

资金

  1. Slovak research and development agency [APVV-14-0753, VEGA2/0162/14]
  2. European Research Council under the European Union's Seventh Framework Program (FP)/ERC [311532]
  3. European Commission FP7 Programme through the Marie Curie Initial Training Network PROSENSE [317420, 20122016]
  4. Research & Development Operational Program - ERDF

向作者/读者索取更多资源

The main aim of the research was to design a functional impedimetric biosensor able to glycoprofile prostate specific antigen (PSA), a biomarker for prostate cancer (PCa), with high specificity using lectins as glycan recognising proteins. Traditionally, full-length antibody is immobilised on the biosensor interface for specific capture of PSA with subsequent glycoprofiling of PSA by addition of lectins. Since full-length antibodies contain glycans in the Fc domain, particular attention has to be paid to suppress direct binding of lectins to immobilised full-length antibodies, which would compromise accurate glycoprofiling. This issue is addressed here using a recombinant single-chain antibody fragments (scAb), which do not contain any carbohydrate moiety. Surface plasmon resonance was applied to prove negligible interaction of lectins with immobilised scAb fragments, while substantial binding of lectins to full length antibodies was observed. Eight different biosensor designs were tested for their ability to detect PSA. The biosensor device based on scAb fragments covalently immobilised on the gold electrode surface, patterned by a mixed SAM using standard amine coupling chemistry, proved to be the most sensitive. The scAb fragment-based biosensor exhibited sensitivity of 15.9 +/- 0.8% decade (1) (R-2 = 0.991 with an average RSD of 4.9%), while the full antibody-based biosensor offered sensitivity towards PSA of 4.2 +/- 0.1% decade (1) (R-2 = 0.999 with an average RSD of 4.8%). Moreover, the selectivity of the scAb-based biosensor was tested using a kallikrein 2 protein, a protein structurally similar to PSA, and the results indicated high selectivity for PSA detection. (C) 2017 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据