Building air leakage analysis for individual apartments in North China

期刊

BUILDING AND ENVIRONMENT
卷 122, 期 -, 页码 105-115

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2017.06.007

关键词

Apartment; Airtightness; Natural ventilation; Energy conservation; Indoor air quality

资金

  1. Ministry of Science and Technology of the People's Republic of China [2014BAJ01B04]

向作者/读者索取更多资源

There is little known on the airtightness performance of apartment building in China. The present study intends to investigate the airtightness performance of twelve individual apartments from four buildings in China's cold area using the blower door method. The air leakage of two building components of each of the three individual apartments from the 4# building was further investigated by a series of blower door tests. The normality test was performed to the test results, and the correlation coefficients between the air leakage and possible influence factors were analyzed. Test results show that the air change rate of the tested individual apartments at 50Pa changes from 1.14 h(-1) to 2.44 h(-1) with an average of 1.77 h(-1). The check valves at the inlets of the discharge flue and exhaust airway were tested to be leakier than the outer windows and doors in the three measured apartments from the 4# building. Results of statistical analysis show that the data was significantly drawn from a normally distributed population at the 0.05 significance level, and the envelope area and the joint length of the opening part of the windows and doors were identified as the main factors that influence the air leakage of the tested apartments at the 0.05 significance level. (C) 2017 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据