4.6 Review

Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation: a Cochrane Systematic Review

期刊

BRITISH JOURNAL OF ANAESTHESIA
卷 119, 期 3, 页码 369-383

出版社

ELSEVIER SCI LTD
DOI: 10.1093/bja/aex228

关键词

anaesthesia; hypoxia; intubation; laryngoscopes

资金

  1. National Institute for Health Research: Cochrane Collaboration Programme Grant [10/4001/04]
  2. National Institute for Health Research [10/4001/04] Funding Source: researchfish

向作者/读者索取更多资源

Difficulties with tracheal intubation commonly arise and impact patient safety. This systematic review evaluates whether videolaryngoscopes reduce intubation failure and complications compared with direct laryngoscopy in adults. We searched CENTRAL, MEDLINE, Embase and clinicaltrials.gov up to February 2015, and conducted forward and backward citation tracking. We included randomized controlled trials that compared adult patients undergoing laryngoscopy with videolaryngoscopy or Macintosh laryngoscopy. We did not primarily intend to compare individual videolaryngoscopes. Sixty-four studies (7044 participants) were included. Moderate quality evidence showed that videolaryngoscopy reduced failed intubations (Odds Ratio (OR) 0.35, 95% Confidence Interval (CI) 0.19-0.65) including in participants with anticipated difficult airways (OR 0.28, 95% CI 0.15-0.55). There was no evidence of reduction in hypoxia or mortality, but few studies reported these outcomes. Videolaryngoscopes reduced laryngeal/airway trauma (OR 0.68, 95% CI 0.48-0.96) and hoarseness (OR 0.57, 95% CI 0.36-0.88). Videolaryngoscopy increased easy laryngeal views (OR 6.77, 95% CI 4.17-10.98) and reduced difficult views (OR 0.18, 95% CI 0.13-0.27) and intubation difficulty, typically using an 'intubation difficulty score' (OR 7.13, 95% CI 3.12-16.31). Failed intubations were reduced with experienced operators (OR 0.32, 95% CI 0.13-0.75) but not with inexperienced users. We identified no difference in number of first attempts and incidence of sore throat. Heterogeneity around time for intubation data prevented meta-analysis. We found evidence of differential performance between different videolaryngoscope designs. Lack of data prevented analysis of impact of obesity or clinical location on failed intubation rates. Videolaryngoscopes may reduce the number of failed intubations, particularly among patients presenting with a difficult airway. They improve the glottic view and may reduce laryngeal/airway trauma. Currently, no evidence indicates that use of a videolaryngoscope reduces the number of intubation attempts or the incidence of hypoxia or respiratory complications, and no evidence indicates that use of a videolaryngoscope affects time required for intubation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据