4.8 Article

An amplified comparative fluorescence resonance energy transfer immunosensing of CA125 tumor marker and ovarian cancer cells using green and economic carbon dots for bio-applications in labeling, imaging and sensing

期刊

BIOSENSORS & BIOELECTRONICS
卷 96, 期 -, 页码 308-316

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2017.05.003

关键词

Carbon dot; Aptamer-Antibody; CA125 Immunosensor; Dendrimer-Au nanoparticles; Fluorescence resonance energy transfer; Ovarian-cancer cells; Cellular imaging

资金

  1. Iranian Nanotechnology Initiative
  2. Research Offices of the University of Kurdistan

向作者/读者索取更多资源

CA125, is a marker in the clinical diagnosis of several cancers and currently is the best serum-based tumor marker for ovarian cancer. Here, we developed an ultrasensitive antibody-ssDNA aptamer sandwich-type fluorescence immunosensor for CA125 detection. Based on a novel signal amplification strategy the carbon dots (CDs) functionalized with aptamer (CD-aptamer) used as detection probe and PAMAM-Dendrimers/AuNPs was used for covalent attachment of CA125-antibody and completing the sandwich assay method. By measuring of fluorescence resonance energy transfer (FRET) signals between CDs and AuNPs as nanoquenchers, the fluorescence signal quenched during sandwich complex formed between anti-CA125, CA125 and CDs-Aptamer and decreasing of fluorescence response signal is related to CA125 concentrations. Under optimal conditions, the immunosensor exhibited an extremely low calculated detection limit of 0.5 f g/mL with wide linear range 1.0 fg/mL to 1.0 ng/mL of CA 125. The application of the immunosensor for CA125 detection in serum samples and measuring of ovarian-cancer cells was also investigated. The immunosensor revealed good sensitivity and specificity with ovarian cell concentrations from 2.5x10(3) to 2x10(4) cells/mL with correlation coefficient of 0.9937 and detection limit of 400 cells/mL (4 cell in 10 mu L), indicating potential application of immunosensor in clinical monitoring of tumor biomarkers. Furthermore, the cell viability was not changed upon treatment with CDs probe during 24 h, showing the low cytotoxicity of the probe. More importantly, CDs-antibody hybrid was achieved in selective imaging of the cancer cells over the OVCAR-3 line cells, implying its potential applications in biosensing, as well as in cancer diagnosis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据