4.6 Article

Ni2P nanosheets array as a novel electrochemical catalyst electrode for non-enzymatic H2O2 sensing

期刊

ELECTROCHIMICA ACTA
卷 253, 期 -, 页码 517-521

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.electacta.2017.09.104

关键词

nickel phosphide; nanosheets array; hydrogen peroxide; non-enzymatic; amperometric sensor

向作者/读者索取更多资源

In this communication, we describe the development of nickel phosphide nanosheets array on titanium mesh (Ni2P NA/TM) as a non-precious metal catalyst electrode toward hydrogen peroxide (H2O2) reduction in neutral solution. As an non-enzymatic H2O2 sensor, the Ni2P NA/TM presents superior analytical performances with rapid response time of less than 5 s, a wide linear range of 0.001-20 mM, a low detection limit of 0.2 mM (S/N = 3), and a high sensitivity of 690.7 mA mM(-1)cm(-2), as well as high selectivity and long-term stability. (C) 2017 Elsevier Ltd. All rights reserved.