4.3 Article

Use of 18F-FDG PET-CT imaging to determine internal mammary lymph node location for radiation therapy treatment planning in breast cancer patients

期刊

PRACTICAL RADIATION ONCOLOGY
卷 7, 期 6, 页码 373-381

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.prro.2016.11.001

关键词

-

资金

  1. LeRoy Schecter Foundation
  2. Parasol Foundation
  3. Leo & Pearl Guzik Israel-Antioch Student Assistance Fund

向作者/读者索取更多资源

Purpose: Adjuvant internal mammary lymph node (IMN) radiation is often delivered with 2-dimensional techniques that use anatomic landmarks and predetermined depths for field placement and dose specification. In contrast, 3-dimensional planning uses the internal mammary vessels (IMVs) to localize the IMNs for planning. Our purpose was to determine if localization of the involved IMN (i-IMN) by F-18-labeled fluorodeoxyglucose positron emission tomography-computed tomography (F-18-FDG PET-CT) offers opportunities to improve treatment. Methods and materials: Breast cancer patients (n = 80) who had i-IMNs (n = 112) on PET-CT for initial staging (n = 40) or recurrence (n = 40) were studied. Size, intercostal space (IC), and distance fromskin, sternum, and IMVs were recorded. Effects on 2- and 3-dimensional planning were evaluated. Results: Most i-IMNs (94.6%) were in the first to third ICs. Few were in the fourth (4.5%) or fifth (0.9%) IC. Mean i-IMN depth was 3.4 cm (range, 1.1-7.3 cm). Prescriptive depths of 4, 5, and 6 cm would result in undertreatment of 25%, 10.7%, and 5.3% of IMNs, respectively. Most IMNs (86.6%) were lateral or adjacent to the sternal edge. Only 13.4% of IMNs were posterior to the sternum. Use of the ipsilateral or contralateral sternal edge for field placement increases the risk of geographic miss or excess normal tissue exposure. Most i-IMNs were adjacent to (83%) or <= 0.5 cm (14%) from the IMV edge. Three (3%) were >0.5 cm beyond the IMV edge. The clinical target volume (CTV) defined by the first to third ICs encompassed 78% of i-IMNs. IMN-CTV coverage of i-IMNs increased with inclusion of the fourth IC (82%), 0.5 cm medial and lateral margin expansion (93%), or both (96.5%). Conclusion: Two-dimensional treatment techniques risk geographic miss of IMNs and exposure of excess normal tissue to radiation. An IMN-CTV defined by the IMVs from the first to third ICs with 0.5-cm medial and lateral margin expansion encompasses almost all i-IMNs identified on PET-CT imaging. Inclusion of the fourth IC offers modest coverage improvement, and its inclusion should be weighed against potential increase in cardiac exposure. (C) 2016 Published by Elsevier Inc. on behalf of the American Society for Radiation Oncology.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据