4.7 Article

Excess Ventilation in Chronic Obstructive Pulmonary Disease-Heart Failure Overlap Implications for Dyspnea and Exercise Intolerance

期刊

出版社

AMER THORACIC SOC
DOI: 10.1164/rccm.201704-0675OC

关键词

ventilation; exercise; chronic obstructive pulmonary disease; cardiopulmonary exercise test

资金

  1. Queen's University
  2. Capes, Brazil
  3. Southeastern Ontario Academic Medical Association, Canada

向作者/读者索取更多资源

Rationale: An increased ventilatory response to exertional metabolic demand (high V-E/V-CO2 relationship) is a common finding in patients with coexistent chronic obstructive pulmonary disease and heart failure. Objectives: We aimed to determine the mechanisms underlying high V-E/V-CO2 and its impact on operating lung volumes, dyspnea, and exercise tolerance in these patients. Methods: Twenty-two ex-smokers with combined chronic obstructive pulmonary disease and heart failure with reduced left ventricular ejection fraction undertook, after careful treatment optimization, a progressive cycle exercise test with capillary (c) blood gas collection. Measurements and Main Results: Regardless of the chosen metric (increased V-E-V-CO2 slope, V-E/V-CO2 nadir, or end-exercise V-E/V-CO2), ventilatory inefficiency was closely related to Pc-CO2 (r values from -0.80 to -0.84; P < 0.001) but not dead space/tidal volume ratio. Ten patients consistently maintained exercise Pc-CO2 less than or equal to 35 mm Hg (hypocapnia). These patients had particularly poor ventilatory efficiency compared with patients without hypocapnia (P < 0.05). Despite the lack of between-group differences in spirometry, lung volumes, and left ventricular ejection fraction, patients with hypocapnia had lower resting Pa-CO2 and lung diffusing capacity (P < 0.01). Excessive ventilatory response in this group was associated with higher exertional Pc-O2. The group with hypocapnia, however, had worse mechanical inspiratory constraints and higher dyspnea scores for a given work rate leading to poorer exercise tolerance compared with their counterparts (P < 0.05). Conclusions: Heightened neural drive promoting a ventilatory response beyond that required to overcome an increased wasted ventilation led to hypocapnia and poor exercise ventilatory efficiency in chronic obstructive pulmonary disease-heart failure overlap. Excessive ventilation led to better arterial oxygenation but at the expense of earlier critical mechanical constraints and intolerable dyspnea.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据