4.5 Article Proceedings Paper

Surface isoelectric focusing (sIEF) with carrier ampholyte pH gradient

期刊

ELECTROPHORESIS
卷 38, 期 20, 页码 2565-2575

出版社

WILEY
DOI: 10.1002/elps.201600565

关键词

Carrier ampholyte; Isoelectric focusing; Miniaturization; Protein separations; Surface printing

资金

  1. National Science Foundation [CBET-CBE 1159763]
  2. NSF CBET-CBE [1548107]
  3. departmental Teaching Assistantships

向作者/读者索取更多资源

Isoelectric focusing (IEF) is a powerful tool for amphoteric protein separations because of high sensitivity, bio-compatibility, and reduced complexity compared to chromatography or mechanical separation techniques. IEF miniaturization is attractive because it enables rapid analysis, easier adaptation to point of care applications, and smaller sample demands. However, existing small-scale IEF tools have not yet been able to analyze single protein spots from array libraries, which are ubiquitous in many pharmaceutical discovery and screening protocols. Thus, we introduce an in situ, novel, miniaturized protein analysis approach that we have termed surface isoelectric focusing (sIEF). Low volume printed sIEF gels can be run at length scales of approximate to 300m, utilize approximate to 0.9ng of protein with voltages below 10V. Further, the sIEF device platform is so simple that it can be integrated with protein library arrays to reduce cost; devices demonstrate reusability above 50 uses. An acrylamide monomer solution containing broad-range carrier ampholytes was microprinted with a Nano eNabler(TM) between micropatterned gold electrodes spaced 300m apart on a glass slide. The acrylamide gel was polymerized in situ followed by protein loading via printed diffusional exchange. A pH gradient formed via carrier ampholyte stacking when electrodes were energized; the gradient was verified using ratiometric pH-sensitive FITC/TRITC dyes. Green fluorescent protein (GFP) and R-phycoerythrin (R-PE) were utilized both as pI markers and to test sIEF performance as a function of electric field strength and ampholyte concentration. Factors hampering sIEF included cathodic drift and pH gradient compression, but were reduced by co-printing non-ionic Synperonic (R) F-108 surfactant to reduce protein-gel interactions. sIEF gels achieved protein separations in <10min yielding bands < 50m wide with peak capacities of approximate to 8 and minimum pI differences from 0.12 to 0.14. This new sIEF technique demonstrated comparable focusing at approximate to 100 times smaller dimensions than any previous IEF. Further, sample volumes required were reduced four orders of magnitude from 20L for slab gel IEF to 0.002L for sIEF. In summary, sIEF advantages include smaller volumes, reduced power consumption, and microchip surface accessibility to focused bands along with equivalent separation resolutions to prior IEF tools. These attributes position this new technology for rapid, in situ protein library analysis in clinical and pharmaceutical settings.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据