4.8 Article

Conceptual development of a building-integrated photovoltaic-radiative cooling system and preliminary performance analysis in Eastern China

期刊

APPLIED ENERGY
卷 205, 期 -, 页码 626-634

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2017.08.011

关键词

Photovoltaic; Radiative cooling; Building; Spectral selectivity

资金

  1. National Science Foundation of China [NSFC 51476159]
  2. National Science and Technology Support Program [2015BAD19B02]
  3. Dongguan Innovative Research Team Program [2014607101008]
  4. International Technology Cooperation Program of Anhui Province of China [BJ2090130038]
  5. Fundamental Research Funds for the Central Universities

向作者/读者索取更多资源

Building -integrated photovoltaic/thermal (BIPV/T) technology has been receiving considerable research attention because of its ability to generate electricity and thermal energy simultaneously. However, space cooling is crucial for buildings in hot regions where space heating is of little use. This study proposed a building integrated photovoltaic-radiative cooling system (BIPV-RC) that can generate electricity via photovoltaic (PV) conversion during daytime and generate cooling energy via radiative cooling (RC) during nighttime to satisfy the demand in such areas. The selective plate, which is the main component of the BIPV RC system, exhibits high spectral absorptivity (emissivity) in the PV conversion band of crystalline silicon solar cells and in the atmospheric window band (i.e., 0.3-1.1 gm and 8-13 pm), as well as low spectral absorptivity (emissivity) in other bands. A quasi-steady-state mathematical model was built, and its performance tinder realistic ambient conditions was analyzed. The electrical efficiencies of the BIPV RC and conventional BIPV systems were then compared under different solar radiations. Comparison results show that the annual electricity production and cooling energy gain of the BIPV RC system in Hefei reached 156.74 kW h m(-2) (equivalent to 564.26 MJ m(-2)) and 579.91 MJ m(-2), respectively. The total electricity production and cooling energy gain of this system are 96.96% higher than those of the BIPV system. Parametric studies show that the precipitable water vapor amount has remarkable effects on the nocturnal RC performance of the BIPV RC system. A small precipitable water vapor amount corresponds to a high nocturnal RC power, thereby implying that a dry climate condition benefits the nocturnal RC of this system.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据