4.7 Article

Kinetics of inactivation and photoreactivation of Escherichia coli using ultrasound-enhanced UV-C light-emitting diodes disinfection

期刊

ULTRASONICS SONOCHEMISTRY
卷 35, 期 -, 页码 471-477

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.ultsonch.2016.10.028

关键词

Ultrasound enhancement; UV disinfection; Photoreactivation; Kinetics model

资金

  1. National Natural Science Foundation of China [50978027]
  2. Fundamental Research Funds for the Central Universities [FRF-IC-15-004]

向作者/读者索取更多资源

Ultraviolet (UV) disinfection is highly recommended owing to its high disinfection efficiency and disinfection by-products free, and UV Light-Emitting Diodes (UV LEDs) is increasingly becoming an alternative of mercury UV lamps for water disinfection owing to its long lifetime, low input power, and absence of problems on disposal. However, renovation of existing UV lamps faces the challenges for UV disinfection associated with disinfection efficiency and photoreactivation, and modified UV disinfection process is required for practical application. In this study, mathematical rule of disinfection and photoreactivation in a US enhanced UV disinfection system was investigated. UV LED with peak emission at 254 nm (UV-C LED) was selected as representative for UV lamps, and a low frequency US was used as pretreatment followed by UV disinfection. The disinfection efficiency of Escherichia coli in deionized water (DI), DI water with kaoline suspension (DIK), and secondary effluent (SE) of municipal wastewater treatment plant were analyzed. Moreover, photoreactivation of E. coli in DIK water within 6 h after disinfection was conducted. The experimental results showed that the disinfection efficiencies had good fit with Chick Watson first-order linear model, and US pretreatment increased the inactivation rate constant for E. coli, which increased from 0.1605 to 0.1887 in the DIK water. Therefore, US pretreatment with UV disinfection have potential to shorten the retention time and reduce the reactor volume. Moreover, the number of photoreactivated E. coli in effluent was reduced under UV-C LED disinfection with US pretreatment compared with that under UV-C LED disinfection alone. The order of maximum percentage of photo-reactivated E. coli was as follows: UV-C LED disinfection alone at 30 mJ/cm(2) > UV-C LED disinfection at 25 mJ/cm(2) with US pretreatment > UV-C LED disinfection at 30 mJ/cm(2) with US pretreatment. The survival ratio versus photoreactivation time showed a good fit to second-order logistic model. US pretreatment in UV-C LED disinfection could improve disinfection efficiency, reducing photoreactivation in the effluent as well, which offers a promising practical application technology. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据