4.7 Article

Improved potentiometric SECM imaging of galvanic corrosion reactions

期刊

CORROSION SCIENCE
卷 129, 期 -, 页码 136-145

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.corsci.2017.10.006

关键词

Copper; Zinc; Scanning electrochemical microscopy; Ion selective microelectrode; Galvanic corrosion; Local pH distribution

资金

  1. Spanish Ministry of Economy and Competitiveness (MINECO, Madrid)
  2. European Regional Development Fund [CTQ2016-80522-P]
  3. National Research, Development and Innovation Office (Budapest, Hungary) [K125244]
  4. Environmental industry related innovative trans- and interdisciplinary research team development in the University of Pecs knowledge base [SROP-4.2.2.D-15/1/Konv-2015-0015]
  5. Erasmus Mobility programme

向作者/读者索取更多资源

The galvanic corrosion of Zn-Cu systems has been monitored in situ using scanning electrochemical microscopy in the potentiometric mode. Here, the initial studies performed using double-barrel microelectrodes for the simultaneous detection of local pH and Zn ion concentration changes in single lines scans, have been extended to the obtention of 2-D maps of Cu2+ and Zn2+ ions. The construction and calibration of a novel Cu2+ ion selective microelectrode is reported. New scanning algorithms and data evaluation tools have been explored for faster acquisition rates than those limited by the time constants associated to potentiometric response.