4.2 Article

Comparative building performance evaluation of a 'sustainable' community centre and a public library building

期刊

出版社

SAGE PUBLICATIONS LTD
DOI: 10.1177/0143624417717202

关键词

Building performance evaluation; energy efficiency; performance gap; public; civic buildings

资金

  1. Innovate UK's BPE programme [450003, 450048]

向作者/读者索取更多资源

This paper uses a forensic building performance evaluation approach to undertake a comparative evaluation of the in-use energy and environmental performance data (collected over two years) of two civic buildings located in Southeast England - a small community centre (<1000m(2)) and a medium-sized public library building (approximate to 4500m(2)), which are designed to high sustainability standards (EPC A rating) and low heating demand met by on-site low/zero carbon technologies. Although both buildings achieved measured air-permeability rates of approximate to 5m(3)/h.m(2), they encountered similar issues related to poor documentation of as-built' drawings, poor handover and guidance, problems with integrating and maintaining new technologies (heat pumps, biomass boilers and solar thermal), lack of calibration of sub-meters, and issues with automatic window controls. However, the actual annual energy use of the community centre is similar to the design prediction, while it is almost double the prediction in the case of the library building. This is because the community centre management team overcame some of the issues through their continuous engagement and interest in the building's performance, whereas the management team of the Library building failed to engage with energy management, resulting in disuse of the biomass boiler and solar thermal system. Practical application: Comparative building performance evaluation (BPE) systematically reveals the similarities and differences in the actual energy and environmental performance of two sustainable' civic buildings. Careful management of heating and electricity loads, good occupant control over the indoor environment and high performance of low-carbon technologies in the Community Centre results in the building performing better than good practice benchmark. Regular changes in facility management (FM) staff result in inadequate energy management and control over heating, ventilation and lighting, that undermines occupant comfort and leads to excessive energy use in the library building. For civic buildings to perform as designed, it is vital that metering, sub-metering and controls are set up, commissioned and used properly by the FM team. Design teams should ensure that easy-to-understand user guides are made available before handover for FM and occupants.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据