3.8 Proceedings Paper

DNA Biosensor for Detection of Salmonella typhi from Blood Sample of Typhoid Fever Patient Using Gold Electrode Modified by Self-Assembled Monolayers of Thiols

出版社

AMER INST PHYSICS
DOI: 10.1063/1.4983937

关键词

-

资金

  1. Penelitian Unggulan Perguruan Tinggi Program of Direktorat Jendral Pendidikan Tinggi, Kementrian Pendidikan dan Kebudayaan, Indonesia

向作者/读者索取更多资源

Electrochemical biosensors are currently being developed in order to handle various clinical problems in diagnosing infectious diseases caused by pathogenic bacteria, or viruses. On this research, voltammetric DNA biosensor using gold electrode modified by thiols with self-assembled monolayers had been developed to detect a certain sequence of Salmonella typhi DNA from blood sample of typhoid fever patient. Thiol groups of cysteamines (Cys) and aldehyde groups from glutaraldehydes (Glu) were used as a link to increase the performance of gold electrode in detecting guanine oxidation signal of hybridized S. typhi DNA and ssDNA probe. Standard calibration method was used to determine analytical parameters from the measurements. The result shown that, the detection of S. typhi DNA from blood sample of typhoid fever patient can be carried out by voltammetry using gold electrode modified by self-assembled monolayers of thiols. A characteristic oxidation potential of guanine using Au/Cys/Gluwas obtained at +0.17 until +0.20 V. Limit of detection and limit of quantification from this measurements were 1.91 mu g mL(-1) and 6.35 mu g mL(-1). The concentration of complement DNA from sample was 6.96 mu g mL(-1).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据