期刊
SENSORS AND ACTUATORS B-CHEMICAL
卷 242, 期 -, 页码 728-735出版社
ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2016.11.122
关键词
CuCo2O4; Porous reduced graphene oxide; Electrochemical sensor; Metal-organic framework; Glucose
资金
- National Natural Science Foundation of China [21277105, 21075092]
A hollow CuCo2O4 polyhedron/porous reduced graphene oxide (PrGO) composite was prepared by simple thermolysis-induced transformation of heterobimetallic zeolitic imidazolate frameworks/porous graphene oxide (Cu-Co-ZIFs/PGO). In this strategy, the PGO was suitable for Cu-Co-ZIFs growing and anchoring, and the framework acted as sacrificial template during the formation of morphology-inherited hollow polyhedrons. In the obtained composite, PrGO sheets not only provided conduction path, but also served as protective agent to prevent the aggregation of crystals. The hollow rhombic dodecahedral CuCo2O4 possessed plentiful active sites and high electrocatalytic activity. When the composite was optimized and used for glucose sensing, it displayed good performance with a wide linear range of 0.5-3354 mu M, a low detection limit of 0.15 mu M (s/N=3), a high sensitivity of 2426 mu AmM-1 cm(-2) and short response time (<3 s). Moreover, it could resist the interference of coexistent substances from serum sample etc. Thus the composite modified glassy carbon electrode was a promising enzyme-free glucose sensor. (C) 2016 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据