4.7 Article

Ultrasensitive electrochemical biosensor for silver ion based on magnetic nanoparticles labeling with hybridization chain reaction amplification strategy

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 249, 期 -, 页码 431-438

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2017.04.108

关键词

Silver ion; Magnetic nanoparticles; Cytosine-Ag+-cytosine; Hybridization chain reaction; Electrochemical biosensor

资金

  1. National Natural Science Foundation of China [21565031, 21665027, 21463028]
  2. YMU-DEAKIN International Associated Laboratory on Functional Materials
  3. Postgraduate Innovation Fund Project by Yunnan Minzu University [2016YJCXS26]
  4. open funding project of the State Key Laboratory of Chemo/Biosensing and Chemometrics, Hunan University, PR China [2013014]

向作者/读者索取更多资源

Silver ion (AgE) is a highly toxic heavy metal ion to aquatic organisms and accumulates in the human body via the food chain. Therefore, fast and accurate detection of Ag+ in water and food resources has become a critical issue within the scope of human health. Herein, we developed an ultrasensitive electrochemical biosensor for detection of Ag+ based on magnetic Fe3O4@gold core-shell nanoparticles (Fe3O4@Au NPs) labeling with hybridization chain reaction (HCR) amplification strategy. In this sensing strategy, the magnetic Fe3O4@Au NPs were selected for labeling with HCR product and enrichment on the surface of magnetic gold electrode. Thiolated-oligonucleotide (S1) was firstly immobilized on the surface of Fe3O4@Au NPs through Au-S chemical bond. In the presence of Ag+, cytosine-rich DNA oligonucleotide S2 hybridized with S1 to form an intramolecular duplex, in which Ag+ can selectively bind to cytosine-cytosine mismatches forming C-Ag+-C complex. The exposed stem of the C-Ag+-C complex opened two alternating ferrocene-labeled DNA hairpins (H-1 and H-2) in turn and triggered HCR to form a supersandwich DNA structure on the surface of Fe3O4@Au NPs. The HCR products modified Fe3O4@Au NPs were brought to the surface of magnetic gold electrode for direct electrochemical measurements. The proposed strategy led to a low detection limit of 0.5 fM and a wide dynamic range of 1 fM-100 pM for target Ag+. The developed biosensor was highly selective and its practical applicability in tap water and lake water samples was also investigated with a satisfactory result. (C) 2017 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据