4.7 Article

Highly sensitive porous carbon and metal/carbon conducting nanofiber based enzymatic biosensors for triglyceride detection

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 246, 期 -, 页码 202-214

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2017.02.050

关键词

Carbon nanofibers; Silver-carbon composite nanofibers; Electrospun nanofibers; Biosensor; Triglyceride; Electrochemical technique

资金

  1. DST Unit of Excellence on Soft Nanofabrication at Indian Institute of Technology Kanpur from the Department of Science and Technology, New Delhi, India

向作者/读者索取更多资源

Electrospinning was employed to synthesize a Ag nanoparticle (NP)-impregnated partially aligned and free-standing carbon nanofibers (CNFs) mat using a polyacrylonitrile (PAN) and silver nitrate blend followed by carbonization. Pyrolyzation of the PAN/AgNO3 blend produced the nanoporous CNFs, and the Ag NPs were grown within the CNFs via thermal decomposition of AgNO3. The fiber diameters of the synthesized CNFs ranged from 130 to 190 nm, and the size of the impregnated Ag NPs was similar to 30 nm. The presence of the Ag NPs enhanced the electrical conductivity and promoted graphitization of the CNFs via the templating effect of the Ag NPs. These synthesized CNFs and AgCNFs nanocomposite were electrophoretically deposited onto indium tin oxide electrodes for detection of triglyceride molecules. Oxygen plasma treatment of the CNFs and AgCNFs surfaces resulted in enhanced loading of lipase and glycerol dehydrogenase bienzymes. The AgCNFs nanocomposite exhibited faster electron transfer than the CNFs, as corroborated by electrochemical impedance spectroscopy and cyclic voltammetry studies. Covalent functionalization via 1-ethy1-3-(3-dimethylaminopropyl)carbodiimide/N-hydroxysuccinimide coupling chemistry on a nanoporous CNFs surface led to higher stability of the fabricated biosensor toward triglyceride detection. The sensitivity was four-fold higher for the AgCNFs (1.232 mu A mg/dL(-1) cm(-2)) bio-electrode compared with the CNFs (0.33 mu A mg/dL(-1) cm(-2)) over a wide detection range (25-500 mg/dL). These biosensors exhibited excellent selectivity, good reproducibility, and faster response (10 s). Thus, enhanced graphitization and electrical conductivity of nanoporous CNFs via incorporation of Ag NPs yields a promising platform for the detection of triglyceride (TG) biomolecules. (C) 2017 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据